PLAY / PAUSE / STOP are drawn as full 14-segment letters (box-drawing
diagonals, a split middle bar, centre strokes) with faint unlit segments,
so the word no longer mixes segment and dot-matrix styles. Unlit lamps are
brighter and keep their level at night; the balance marker is two thin
segments over a bright centre mark; analyzer peak marks hold, then fall with
growing speed; and the lower-right block is one digital module with captions
and equally tall digits for track and volume.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A new CycleVisualizerMode action (Shift+M by default) steps the fullscreen
visualizer's display mode; the choice is saved in visualizations.toml and
reaches scripts as input.mode. The VFD panel uses it for its classic, focus,
minimal and tape modes, with a row of mode lamps after each change and a
step-down when a mode does not fit the window.
Polish: quieter signal-path lines with lit boxes and nodes, two-cell peak
marks and a mid-level red zone in the level meter, A and Y in a 14-segment
style with thin diagonals, an analyzer tint from warm amber in the bass to
light yellow in the treble, and bar inertia that is separate from peak hold.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The analyzer shows three levels of glow (a dimmer foot, the body, a nearly
white top segment), faint unlit segments and a light peak-hold mark, on a
nonlinear scale; loud columns glow brighter on their own instead of the
whole panel brightening. The peak frequency becomes one measuring module
(caption, held value, rule, sample rate) with a real hold. The signal path
is a schematic of framed boxes on a bus with nodes, a wire to the lower row,
a pulse that now and then runs along it and a SIGNAL PATH state label.
PLAY / PAUSE / STOP use segment letters with centre strokes, mode lamps get
indicator bars, paused colours fade into unlit phosphor, and a new source
goes dark and relights with its value. LAYOUT() chooses between the full
panel, a spectrum focus and a tape deck composition, or picks by size.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Verticals of the segment digits now use quarter blocks, as thick as the
eighth-block horizontals, and the mesh behind them is gone; unlit segments
are fainter so lit digits read clearly. The routing display uses label
plates without sides, and its wire runs along cell edges from the volume
plate's corner straight down to the tone plate's corner, so it joins
cleanly. The bass / treble fans are single thin strokes instead of braille
lines, and the braille amplifier and speakers are gone.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The VFD panel gains a dot-matrix title line (5x7 Latin and Cyrillic in
braille, smooth scrolling), palettes, optional needle VU meters, a night
dimmer, a filament "breath" and loudness brightening, uneven digit
brightness, a mesh behind the big digits, a tape counter, LOUDNESS / MUTE /
SEARCH lamps, a burst of static on track and source changes, and a standby
clock with a sweep at the top of every minute.
The visualization clock now shows local time (it showed UTC), and scripts
get clock_hour, clock_minute, clock_second and clock_millis from the same
reading.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Scripts now receive the spectrum, channel levels, sample rate and track,
queue and transport details; may return #{ commands, state } to keep state
between frames (with dt and frame, reset on reload and on opening); can draw
thin braille dots and lines (clipped to the area); and can set bold, dim,
italic, underline or reversed on any command. v2 scripts keep working.
The bundled "VFD panel" preset uses all of it for a vacuum-fluorescent hi-fi
front panel in a thin style: segment counter, peak level meter, 25-band
analyzer with peak hold, tone fans, routing diagram and transport lamps,
with a power-on segment test, a counter search on track changes and an
OVER lamp.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>